The compact GammaView is light, easy to carry and operate with a 1x1 Nal scintillation detector that accurately measures gamma contamination and exposure. Perfect for use in the lab, facility, and in the field.
The GammaView can also be used as a single-channel analyzer (SCA). This function allows a “window” to be set to focus on a specific energy region of the gamma spectrum, effectively reducing the background count.
Features Included:
Adjustable Timer, Selectable Alert, On-board Memory, Bluetooth, Free Software
Specific Applications Include:
Compliance monitoring, environmental monitoring, remote monitoring, health physics, homeland defense.
Gamma Scintillator Detector:
1x1 NaI Scintillation Probe. 2.5 cm (1 in) dia. x 2.5 cm (1 in) thick with C Connector
The GammaView is optimized for use with the included 1x1 NaI probe.
Please contact us for different probe options.
Operating Range:
mR/hr – 1 μR/h to 5 mR/h
μSv/hr - 0.001 to 50
CPM – 0 to approx. 875,000
CPS – 0 to approx. 14,584
Total Counts- 999,999
Energy Range:
20 Kev to 1.5 MeV
Typical sensitivity:
150 CPM/µR/hr.
|
Accuracy:
±10% with Source Calibration (Referenced to Cs137)
Operating Voltage:
Typically 500 to 1200 Volts
Selectable Alert Set Range:
mR/hr - 1 μR/h to 5 mR/h
μSv/hr - 0.001 to 50
CPM - 1 to 875,000
CPS- 1 to 14,584
Pulsating beeper sounds the alert.
Display:
Graphic Display with Backlight
Averaging Periods:
Display updates every 3 seconds. At low background
levels, the update is the average for the past 30-second time
period. The timed period for the average decreases as the
radiation level increases.
Anti-Saturation:
Meter will hold at OVER RANGE in fields as high as 100 times
the maximum reading.
Outputs:
USB for use with Free Observer USB Software for PCs
Bluetooth for use with the Free Observer BLE App for Android.
Count Light:
Red LED flashes with each radiation event.
Audio Indicator:
Internally mounted beeper (can be switched off for silent operation)
Power Requirements:
Two AA alkaline batteries (included). Approx. 500 hrs @ background.
Size:
Base unit - 140 X 68 X 33 mm (5.5 X 2.7 X 1.3 in.), Probe- 5.0 X 18.5 cm (2 x 7.3 in)
Temperature Range:
-15°C to +50°C (14°F to 122°F)
Humidity:
10% to 70% Non-Condensing.
Weight:
Base unit - 193 grams (6.8 oz) with batteries. Probe- 393 grams (13.8 oz)
Includes:
NIST Certificate of Calibration, Carrying Case, Xtreme Boot, Stand, Lanyard, Mini-USB Cable, Free Observer USB Software Download, Free Observer BLE Software Download.
Warranty:
1 Year Limited Warranty