SPECIFICATIONS |
pH Range |
-2.00 to 16.00 pH; -2.000 to 16.000 pH |
mV Range |
±699.9 mV; ±2000 mV |
EC Range |
0.00 to 29.99 µS/cm; 30.0 to 299.9 µS/cm; 300 to 2999 µS/cm; 3.00 to 29.99 mS/cm; 30.0 to 200.0 mS/cm; up to 500.0 mS/cm uncompensed EC* |
TDS Range |
0.0 to 14.99 mg/l (ppm); 15.0 to 149.9 mg/l (ppm); 150 to 1499 mg/l (ppm); 1.50 to 14.99 g/l (ppt); 15.0 to 100.0 g/l (ppt); up to 400.0 g/l actual TDS* (with 0.80 factor) |
NaCl Range |
0.0 to 400.0% |
Temp Range |
-20.0 to 120.0°C / -4.0 to 248.0°F |
pH Resolution |
0.01 pH; 0.001 pH |
mV Resolution |
0.1 mV; 1 mV |
EC Resolution |
0.01 µS/cm; 0.1 µS/cm; 1 µS/cm; 0.01 mS/cm; 0.1 mS/cm; |
TDS Resolution |
0.01 mg/l; 0.1 mg/l; 1.0 mg/l; 0.01 g/l; 0.1 g/l |
NaCl Resolution |
0.1% |
Temp Resolution |
0.1°C / 0.1°F |
pH Accuracy |
±0.01 pH; ±0.002 pH |
mV Accuracy |
±0.2 mV; ±1 mV |
EC Accuracy |
±1% of reading ±(0.05 µS/cm or 1 digit) |
TDS Accuracy |
±1% of reading ±(0.03 ppm or 1 digit) |
NaCl Accuracy |
±1% of reading |
Temp Accuracy |
±0.4°C / ±0.8°F |
Rel mV Offset |
±2000 mV |
pH Calibration |
1, 2 or 3 points calibration, with 7 memorized buffers (pH 1.68, 4.01, 6.86, 7.01, 9.18, 10.01 and 12.45) |
EC Calibration |
1 point slope calibration with 6 memorized solutions: (84 µS/cm, 1413 µS/cm, 5.00 mS/cm, 12.88 µS/cm, 80.0 µS/cm, 111.8 mS/cm) |
NaCl Calibration |
1 point |
Temp Calibration |
2 point, at 0 and 50°C / 32 and 122°F |
Temperature Compensation |
automatic or manual, from -20.0 to 120.0°C / -4.0 to 248.0°FF |
Temperature Coefficient |
selectable from 0.00 to 6.00%/°C (EC and TDS only) |
pH Electrodes & Temp Probe |
MA814DB/1 & MA917B/1 & MA831R (included) |
TDS Factor |
0.40 to 0.80 (default value is 0.50) |
Log on demand |
up to 50 samples on each range (pH, mV, EC, TDS, NaCl) |
GLP |
last pH, EC, NaCl calibration data |
PC Interface |
RS232 / USB Opto-isolated |
Environment |
0 to 50°C / 32 to 122°F; max RH 95% |
Power supply |
12 VDC power adapter (included) |
Dimensions |
230 x 160 x 95 mm |
Weight |
0.9 kg |
|
ACCESSORIES |
MA9004 |
pH 4.01 buffer solution, 230 mL bottle |
MA9007 |
pH 7.01 buffer solution, 230 mL bottle |
MA9010 |
pH 10.01 buffer solution, 230 mL bottle |
MA9011 |
Refilling solution for ORP electrode, 230 mL bottle |
MA9060 |
12880 µS/cm calibration solution, 230 mL bottle |
MA9061 |
1413 µS/cm calibration solution, 230 mL bottle |
MA917B/1 |
Glass body, double junction refillable pH electrode |
MA814DB/1 |
Conductivity/Temperature probe with DIN connector and 1 m cable |
MA831R |
Temperature probe |
Mi5200 |
Application Software |
|
ORDERING INFORMATION |
Mi180 is supplied complete with: • MA917B/1 pH Electrode • MA814DB/1 EC/TDS/NaCl/Temperature probe • MA831R Temperature Probe • M10004 pH 4.01 Sachet Buffer Solution • M10007 pH 7.01 Sachet Buffer Solution • M10010 pH 10.01 Sachet Buffer Solution • M10016 Sachet Electrode Cleaning Solution • Mi5200 Application Software • Graduate Pipet, 12 VDC Adapter & Instruction manual
|
|