502X - SyringeONE:OEM Microfluidics Syringe Pump with Stall Detection

Microfluidics Syringe Pump with Stall Detection!
Manufacturer: New Era Instruments
SKU: 502X
Manufacturer part number: 502X
$1,125.00
$1,049.99

NE-500 does not come with a power supply.
Please see OEM Starter Kit and OEM Net below.

  • Computer controllable: networkable up to 100 pumps
  • Stand-alone operation: pre-program the pump with a dispensing program, then operate the pump from an attached Foot Switch, button, or I/O controller
  • Add the OEM Starter Kit to run as a fully functional, stand-alone pump

Description:

  • Does not have a built-in user interface
  • Chassis mountable: 9 1/2"L x 4"W x 4 1/8"H (24.13 x 10.16 x 10.5 cm)
    If chassis does not fit in your system, we make custom designed OEM syringe pumps to accommodate your specific needs.
  • Operates from a 12V DC power source
  • Holds 1 syringe, up to 60 mL. 140 mL with long chassis.
  • Infusion rates from 0.73 µL/hr (1 mL syringe) to 2100 mL/hr (60 mL syringe)
  • Includes all the advanced functions and programming features of the NE-1000 Series
  • Disposable, Glass, Stainless Steel Syringes and Plumbing Supplies are sold separately.
  • Download our free pump terminal emulator or get a trial version of our Windows based SyringePumpPro
  • One-click program upload from "Pumping Program Generator" spreadsheet
  • Custom modifications to the mechanics and firmware are also available

Specifications
Model Style Stall Detection Number of Syringes Maximum Syringe Size NE-1002X Stand-Alone Yes 1 60 mL; 140 mL partially filled NE-502X OEM Yes 1 60 mL; 140 mL partially filled
Rate & Volume Units:
Rate Units: nL/hr, µL/hr, nL/min, µL/min
Volume Units: nL, µL RS-232 Command Modifications from Standard NE-1000 Series
Rate Command: RAT [C | I ] [ <float> [ NM | UM | NH | UH ] ]
 
Volume Target and Set Volume Units Command: VOL [ <float> | { NL | UL } ]
 
NM = nL/min UM = µL/min NH = nL/hr UH = µL/hr NL = nL UL = µL Mechanical
Motor type: Step motor Motor steps per revolution: 400 Motor gearbox reduction: 25:1 Motor to drive screw ratio: 15/28 Drive screw pitch: 20 revolutions/” Micro-stepping:  1/16 to 1/2 depending on motor speed Advance per step: 4.25223214 nm to34.0178571 nm depending on motor speed
 
Dimensions: 8 3/4” x 5 3/4” x 4 1/2” (LxWxH) (Non-OEM versions) (22.86 cm x 14.605 cm  x 11.43 cm) Weight: 3.8 lbs. (1.63 kg) Electrical
Power supply type: External wall adapter, power source specific Power supply output rating: 12V DC @ 1000 mA Power connector: 2.1 mm, center positive, DC Voltage at power connector: 12V DC at full load Amperage: 750 mA at full load Operational
Accuracy: Within 1% error
Reproducibility: Within 0.1% error
Maximum force: 150 lbs. at minimum speed, 18 lbs. at maximum speed
 
Syringe inside diameter range: 0.100 to 50.00 mm Maximum speed: 0.224469144 cm/min Minimum speed: 8.40896E-05 cm/hr Maximum pumping rate: 1246 µL/min with a B-D 60 mL syringe Minimum pumping rate: 14.59 nL/hr with a B-D 1 mL syringe
 
Number of Program Phases: 41
 
RS-232 pump network: 100 pumps maximum RS-232 selectable baud rates: 300, 1200, 2400, 9600, 19200

Product tags